TM 9-2815-210-34-2-2
Table 6-2. Run-In Schedule - Long (Model LDT-465-1C)
NOTE
D u r i n g run-in, oil sump temperature shall not
b e more than 265F. Oil pressure is measured
a t engine oil gallery.
Fuel
G r o s s Brake
(DF-1 of
Duration
E n g i n e Speed
( b a r e engine)
Period
(minutes)
(rpm)
VV-F-800)
0
0
1
(minimum)
P r e l u b r i c a t e at 25
p s i (measured at
e n g i n e oil gallery)
15
1000
Diesel
2
30
Diesel
15
15
1200
3
R e t i g h t e n cylinder head nuts to 157 pound-feet and set valves
4
i m m e d i a t e l y following period 3.
Diesel
1600
33
5
15
Diesel
2000
64
30
6
Diesel
110
2400
7
30
Diesel
2600
125 to 135
8
15
9
S e t high speed adjusting screw to limit maximum speed, no load
2850 to 2900 rpm.
Diesel
2600
130 to 140
10
S e t full load power
(64 lb/hr
m a x . fuel
flow)
Diesel
3 0 5 pound-
P o w e r check full load
1500
11
feet
t o r q u e (min)
(37.5 lb/hr
m a x . fuel
flow)
Diesel
(29 to 30
1200
12
S e t droop screw
lb/hr
fuel
flow)
Note 1
0
Diesel
13
S e t low idle adjust-
ment
Diesel
14
A s needed to check
for leaks
Note 1: Check injection pump data plate for recommended low idle adjustment setting.
|