TM 9-2815-210-34-2-2
Table 6-1. Run-In Schedule - Long (Models LD-465-1 and LD-465-1C)
NOTE
D u r i n g run-in, oil sump temperature shall not
b e more than 260F. O i l pressure is measured
a t engine oil gallery.
Fuel
G r o s s Brake
E n g i n e Speed
(DF-1 of
Duration
(rpm)
Period
(minutes)
VV-F-800)
( b a r e engine)
0
0
1
P r e l u b r i c a t e at 25
(minimum)
p s i (measured at
e n g i n e oil gallery)
15
Diesel
1000
30
2
Diesel
15
1200
15
3
4
R e t i g h t e n cylinder head nuts to 130 pound-feet (157 pound-feet for
T D block) and set valves immediately following period 3.
33
15
1600
Diesel
5
30
2000
64
Diesel
6
Diesel
30
2400
110
7
2600
120 to 130
Diesel
15
8
9
S e t high speed adjusting screw to limit maximum speed, no load
2850 to 2900 rpm.
2600
Diesel
126 to 131
10
Set full load power
(62 lb/hr
m a x . fuel
flow)
1400
Diesel
11
P o w e r check full
3 0 0 pound-
f e e t torque
load
(min)
12
S e t low idle adjust- 650 to 700
0
Diesel
ment
13
A s needed to check
Diesel
for leaks
|