TM 9-2815-210-34-2-2
Table 6-3. Run-In Schedule - Long (Model LDS-465-1)
NOTE
D u r i n g run-in, oil sump temperature shall not
b e more than 265F. Oil pressure is measured
a t engine oil gallery.
Fuel
G r o s s Brake
E n g i n e Speed
(DF-1 of
Duration
Period
VV-F-800)
(minutes)
( b a r e engine)
(rpm)
1
0
0
(minimum)
P r e l u b r i c a t e at 25
p s i (measured at
e n g i n e oil gallery)
1000
2
30
22
Diesel
3
15
1400
40
Diesel
R e t i g h t e n cylinder head nuts to 130 pound-feet (157 pound-feet for
4
T D block) and set valves immediately following period 3.
5
15
1600
60
Diesel
15
2200
120
Diesel
6
7
30
2600
140
Diesel
8
30
2600
170 to 180
Diesel
S e t high speed adjusting screw to limit maximum speed, no load
9
2850 to 2900 rpm.
10
S e t full load power
2600
175 to 185
Diesel
(83 lb/hr
m a x . fuel
flow)
11
Adjust droop screw
1200
(37 to 39
Diesel
lb/hr
or
f u e l flow)
1400
(44 to 45
lb/hr
fuel
flow)
12
P o w e r check full
2000
4 2 5 pound-
Diesel
load
f e e t torque
(min)
(70 lb/hr
m a x . fuel
flow)
13
S e t low idle adjust-
650 to 700
Diesel
0
ment
14
A s needed to check
Diesel
for leaks
|