TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
NOTE
Tag air hose and connection point prior to
disconnecting
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Disconnect air hose from 90 degree fitting
of pressure protection valve.
(2) Remove tube nipple from M1089 30K
winch pneumatic test adapter.
(3) Connect M1089 30K winch pneumatic test
adapter to 90 degree fitting of pressure
protection valve.
(4) Start engine (TM9-2320-366-10-1) and
allow vehicle to build air pressure.
(5) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(6) If 75-120 PSI (518-827 kPa) is not present,
replace pressure protection valve
(para 11-29).
(7) If 75-120 PSI (518-827 kPa) is present,
replace air hose (para 23-5).
(8) Shut down engine (TM 902320-366-10-1).
(9) Drain air tanks (TM9-2320-366-10-1).
(10) Remove STE/ICE-R 0-1000 PSI transducer
from M1089 30K winch pneumatic test
adapter.
(11) Disconnect M1089 30K winch pneumatic
test adapter from 90 degree fitting of
pressure protection valve.
(12) Connect air hose to 90 degree fitting of
pressure protection valve.
(13) Connect input air hose to input tee fitting.
(14) Close LH and RH catwalks.
(15) Install tube nipple on 30K winch
pneumatic test adapter.