aa4. MAIN WINCH LH AND RH FREESPOOLS DO NOT OPERATE (CONT)
WARNING
Read WARNING
KNOWN INFO
TEST OPTIONS
on following page.
5.
Air Pressure Test
LH and RH 30K winches
STE/ICE-R Test #50
operates.
Is 75-120 PSI
REASON FOR QUESTION
STATION SELECTOR switch to
(518-827 kPa) present at
WRECKER CONTROL PANEL.
If 75-120 PSI (518-827 kPa) is
90 degree fitting of pressure
MODE SELECTOR SWITCH to
not present, pressure
protection valve?
NORMAL.
protection valve is faulty. If
MAIN WINCH LH and RH
75-120 PSI (518-827 kPa) is
SPEED switch operates.
present, air hose is faulty.
Terminal block jumper OK.
POSSIBLE PROBLEMS
Faulty pressure protection
NO
valve.
Faulty air hose.
Replace pressure protection
YES
valve (para 11-29).
Replace air hose (para 23-5).
Change 1