e152. M1084/M1086 WORKLIGHTS DO NOT ILLUMINATE
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool Kit, Genl Mech (Item 46, Appendix C)
Engine shut down (TM 9-2320-366-10-1).
STE/ICE-R (Item 41, Appendix C)
Personnel Required
Multimeter, Digital (Item 22, Appendix C)
(2)
References
Materials/Parts
TM 9-4910-571-12&P
Wire, Elect, 50 ft (Item 71, Appendix D)
START
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
1.
One crane worklight
Voltage Test or
on following page.
illuminates.
STE/ICE-R #89
Is 12 vdc present at
POSSIBLE PROBLEMS
REASON FOR QUESTION
connector P136-B
If 12 vdc is not present,
Faulty crane worklight.
(RH worklight) or
wire 2004 is faulty.
Faulty crane power cable
connector P135-B
assembly.
(LH worklight)?
NO
Repair wire 2004 (para 2-45)
YES
or replace crane power
cable assembly (para 7-79).