TM 9-2320-366-20-2
TM
WARNING
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
VOLTAGE TEST
(1)
Disconnect connector P136 (RH worklight)
or P135 (LH worklight).
(2)
Set multimeter to volts dc.
(3)
Connect positive (+) probe of multimeter to
connector P136-B (RH) or P135-B (LH).
(4)
Connect negative (-) probe of multimeter to
ground.
(5)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6)
If 12 vdc is not present, repair wire 2004
(para 2-45) or replace crane power cable
assembly (para 7-79).
(7)
Position master power switch to off
(TM 9-2320-366-10-1).
2-1577