TM 9-2320-366-20-2
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to connector P172 socket D.
(3)
Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(4)
If continuity is not present, repair wire
3079 from connector P172 socket D to
terminal lug TL78 (para 2-45) or replace
dump power cable assembly (para 7-125).
(5)
If continuity is present, repair wire 3079
from connector J172 pin D to connector L7
socket 2 (para 2-45) or replace dump cable
assembly (para 7-124).
(6)
Connect connector P172 to connector J172.
(7)
Start engine (TM 9-2320-366-10-1).
(8)
Engage PTO (TM 9-2320-366-10-1).
(9)
Lower dump body (TM 9-2320-366-10-1).
(10)
Disengage PTO (TM 9-2320-366-10-1).
(11)
Shut down engine (TM 9-2320-366-10-1).
Change 1
|