e142. M1090/M1094 TAILGATE RELEASE DOES NOT OPERATE (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
7.
Continuity Test or
Dump bed raises and lowers.
STE/ICE-R Test #91
Pneumatic system OK.
Is continuity present from
REASON FOR QUESTION
Tailgate release solenoid OK.
connector P172 socket D
Tailgate release switch OK.
If continuity is not present,
to known good ground?
Auxiliary panel cable
wire 3079 in dump power
assembly OK.
cable assembly is faulty.
POSSIBLE PROBLEMS
If continuity is present,
wire 3079 in dump cable
Faulty dump power cable
assembly is faulty.
assembly.
Faulty dump cable
assembly.
NO
Repair wire 3079 from connector
P172 socket D to terminal lug TL78
YES
(para 2-45) or replace dump power
cable assembly (para 7-125).
Repair wire 3079 from connector
J172 pin D to connector L7 socket 2
(para 2-45) or replace dump cable
assembly (para 7-124).