TM 9-2320-366-20-2
e143. M1090/M1094 DUMP BODY DOES NOT RAISE
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool Kit, Genl Mech (Item 46, Appendix C)
Engine shut down (TM 9-2320-366-10-1).
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Personnel Required
Goggles, Industrial (Item 15, Appendix C)
(2)
Sling, Cargo (Item 31, Appendix C)
Lifting Bracket, Dump Body (2) (Item E-24, Appendix E)
References
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
TM 9-4910-571-12&P
Socket Set, Socket Wrench (Item 34, Appendix C)
Materials/Parts
Wire, Elec, 50 ft (Item 71, Appendix D)
NOTE
Perform Electrical System Troubleshooting
e1. Circuit Breaker Does Not Operate on
circuit breaker CB50 prior to beginning
this task.
START
WARNING
CAUTION
Read WARNING and
CAUTION on
KNOWN INFO
TEST OPTIONS
following page.
1.
Voltage Test or
Hydraulic oil level OK.
STE/ICE-R Test #89
PTO OK.
Is 24 VDC present at
REASON FOR QUESTION
Circuit breaker CB50 OK.
connector L8 socket 2?
This question eliminates
POSSIBLE PROBLEMS
possible problems and
determines where
Faulty dump body hydraulic
troubleshooting continues.
system.
Faulty four-way relief valve.
Faulty solenoid valve.
Faulty DUMP BED UP/DOWN
NO
switch.
Faulty auxiliary panel cable
assembly.
Faulty M1090/M1094 dump
cable assembly.
YES
Go to step 5 of this fault.
Faulty M1090/M1094 dump
power cable assembly.
Faulty dashboard cable
assembly.
Change 2