TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
terminal listed in Table 2-14. Actuator
Solenoid Resistance Test.
(3)
Connect negative (-) probe of multimeter on
terminal block TB-C and note reading on
multimeter.
(4)
If resistance is less or greater than value
listed in Table 2-14. Actuator Solenoid
Resistance Test, notify DS Maintenance.
(5)
Install wrecker control panel top cover
(para 17-20).
Function/Solenoid
Terminal Board (+) Position
Solenoid Resistance in Ohms
Underlift fold up - L18
2
81-101
Stinger in - L13
3
81-101
Underlift up - L14
4
81-101
Main winch LH in - L6
6
81-101
Main winch RH in - L1
8
81-101
Main winch RH out - L2
11
81-101
Main winch speed RH high
12
35-45
Main winch LH out - L5
13
81-101
Main winch speed LH high
14
35-45
Underlift down - L11
15
81-101
Stinger out - L16
16
81-101
Underlift fold down - L15
17
81-101
2-1461
|