e141. ONE WRECKER FUNCTION DOES NOT OPERATE FROM WRECKER REMOTE CONTROL (CONT)
e141.
KNOWN INFO
TEST OPTIONS
2.
Circuit breaker CB50 OK.
Resistance Test or
Mode selector switch in
STE/ICE-R Test #91
Is resistance present
REASON FOR QUESTION
NORMAL position.
through actuator
If resistance is not present,
Hydraulic functions OK.
solenoid?
actuator solenoid is faulty.
Station selector switch
in remote control position.
All functions from wrecker
control panel OK.
Wrecker remote
control box OK.
NO
Remote control wiring
harness OK.
POSSIBLE PROBLEMS
Faulty actuator solenoids.
YES
Notify DS Maintenance.
Perform Wrecker Pneumatic Troubleshooting
(aa1. One or More Wrecker Functions Do Not
Operate From Wrecker Remote Control).