TM 9-2320-366-20-2
TM
e141. ONE WRECKER FUNCTION DOES NOT OPERATE FROM WRECKER REMOTE CONTROL (CONT)
e141.
KNOWN INFO
TEST OPTIONS
3.
Circuit breaker CB50 OK.
Continuity Test or
Mode selector switch in
STE/ICE-R Test #91
Is continuity present
REASON FOR QUESTION
NORMAL position.
through remote control
This question eliminates
Hydraulic functions OK.
box?
possible problems and
Station selector switch
determines where
in remote control position.
troubleshooting continues.
All functions from wrecker
control panel OK.
Actuator solenoids OK.
POSSIBLE PROBLEMS
NO
Faulty wrecker remote
control.
Faulty remote control
wiring harness.
YES
Go to step 4 of this fault.
Repair wire (para 2-45) or
replace M1089 remote control
wiring harness (para 7-117).