TM 9-2320-366-20-2
TM
e136. ALL M1089 CONTROL FUNCTIONS DO NOT OPERATE FROM WRECKER CONTROL PANEL
AND WRECKER REMOTE CONTROL
INITIAL SETUP
Tools and Special Tools
Equipment Conditions
Tool Kit, Genl Mech (Item 46, Appendix C)
Top control panel cover removed
Multimeter, Digital (Item 22, Appendix C)
(para 17-20).
STE/ICE-R (Item 41, Appendix C)
Personnel Required
References
(2)
TM 9-4910-571-12&P
START
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
1.
Circuit breaker OK.
Voltage Test or
on following page.
Mode selector switch in
STE/ICE-R Test #89
Is 24 vdc present at
REASON FOR QUESTION
NORMAL position.
This question eliminates
connector P107g?
Hydraulic functions OK.
possible problems and
Pneumatic functions OK.
POSSIBLE PROBLEMS
determines where
Faulty station selector
troubleshooting continues.
switch.
Faulty wrecker control
panel wiring harness.
NO
Faulty dashboard cable
assembly.
Faulty rear lights cable
assembly.
YES
Go to step 4 of this fault.