TM
(1) Loosen four screws on junction box.
(2) Open cover on junction box.
(3) Visually inspect the wiring around terminal
board position 28 for shorted wires that
could put 24 vdc on position 28.
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
terminal board position 19.
(3)
Connect negative (-) probe of multimeter to
terminal board position 1 and note reading
on multimeter.
(4)
If continuity is not present, replace overload
lockout cable (para 7-116).
(5)
If continuity is present, notify DS Maintenance.
(6)
Close cover on junction box.
(7)
Tighten four screws on junction box.
(8)
Connect batteries (para 7-57).