TM 9-2320-366-20-2
TM
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuit
and cause severe burns or electrical shock.
VOLTAGE TEST
(1)
Disconnect connector P107 from connector
J4.
(2)
Set multimeter to volts dc.
(3)
Connect positive (+) probe of multimeter to
connector P107g.
(4)
Connect negative (-) probe of multimeter to
ground.
(5)
Position master power switch to on
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6)
If 24 vdc is not present, go to step 4 of this
fault.
(7)
Position master power switch to off
(TM 9-2320-366-10-1).
(8)
Connect connector P107 to connector J4.
2-1423
|