TM 9-2320-366-20-1
TM
e26. CHEMICAL DETECTOR INDICATOR DOES NOT OPERATE
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool Kit, Genl Mech (Item 46, Appendix C)
Engine shut down (TM 9-2320-366-10-1).
STE/ICE-R (Item 41, Appendix C)
Batteries disconnected (para 7-57).
Multimeter, Digital (Item 22, Appendix C)
Wrench, Torque, 0-75 lb-in. (Item 90, Appendix B)
Personnel Required
(2)
References
TM 9-4910-571-12&P
START
KNOWN INFO
TEST OPTIONS
1.
Chemical alarm operates.
Continuity Test or
STE/ICE-R #91
POSSIBLE PROBLEMS
Is continuity present
Faulty dashboard cable
REASON FOR QUESTION
between lighted indicator
This question eliminates
assembly.
display terminals 2
possible problems and
Faulty chemical detector
and 17?
determines where
indictor lamps.
troubleshooting continues.
Faulty lighted indicator
NO
display.
YES
Go to step 3 of this fault.