Click here to make tpub.com your Home Page

Page Title: CONTINUITY TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-1
TM
CONTINUITY TEST
(1)
Remove PDP cover (para 16-2).
(2)
Remove three screws and washers from PDP.
(3)
Remove three screws from PDP.
(4)
Lift PDP outward to gain access.
(5)
Disconnect connector P111 from connector
J111.
(6)
Set multimeter to ohms.
(7)
Connect positive (+) probe of multimeter to
connector P110-E.
(8)
Connect negative (-) probe of multimeter to
connector P111-D and note reading on
multimeter.
(9)
If continuity is not present, replace CTIS cable
assembly (para 7-60).
(10)
If continuity is present, repair wire 1528
(para 2-45) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(11)
Connect connector P111 to connector J111.
(12)
Install PDP on dashboard with three screws.
(13)
Install three washers and screws in PDP.
(14)
Install PDP cover (para 16-2).
(15)
Connect connector P110 to CTIS ECU.