TM 9-2320-211-34-2-1
Cleaning. There are no special cleaning procedures needed. Refer to
d.
c l e a n i n g procedures given in para 1-3.
I n s p e c t i o n and Repair.
e.
FRAME 1
1.
C h e c k that differential carrier housing (1) and two cap assemblies (2) are not
c r a c k e d o r d i s t o r t e d . I f housing or cap assemblies are damaged, get a new
d i f f e r e n t i a l carrier housing and two new cap assemblies.
2.
C h e c k that adjusting nut threads on differential carrier housing (1), cap
a s s e m b l i e s (2), and two adjusting nuts (3) are not stripped or c r o s s t h r e a d e d .
I f adjusting nuts are damaged, get new one.
3.
C h e c k that tapped holes in differential carrier housing (1) are not stripped or
c r o s s t h r e a d e d . F i x with correct size tap.
GO TO FRAME 2
NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT IN
THIS FRAME. PARTS WITHOUT CALLOUTS ARE SHOWN
ONLY FOR REFERENCE PURPOSES OR ARE CHECKED IN
ANOTHER FRAME.
|