1.
C h e c k that two bearing cups (1) and two bearing cones (2) are not damaged.
R e f e r to para 7-7.  R e p l a c e if damaged.
M o u n t each differential case half (3) in a lathe. Place dial indicator against
2.
f l a n g e that mounts to helical drive gear (4).  C h e c k that runout at flange of
d i f f e r e n t i a l case half is not more than 0.002 inch.
WARNING
Dry cleaning solvent is flammable. Do not use near an
o p e n flame.  K e e p a fire extinguisher nearby when sol-
v e n t i s u s e d .  U s e only in well-ventilated places.
Failure to do this may result in injury to personnel and
d a m a g e to equipment.
I f differential case half (3) runout is more than 0.002 inch, use lathe to cut
3.
a w a y only enough metal to bring runout within limits. Rem-eve burrs with
a honing stone.  C l e a n with solvent.
GO TO FRAME 3
NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT.
PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES.