TM 1-1510-223-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
PRIOR TO MAINTENANCE TEST FLIGHT (CONT)
h.
FIRE PULL handles - In.
i.
# 1 and # 2 FUEL PRESS warning
annunciators - Extinguished.
j.
STANDBY PUMP switches - Off.
k.
#1 and #2 FUEL PRESS
warning
annunciators - Illuminated.
l.
# 1 and # 2 STANDBY PUMP circuit
breakers - In.
m. # 1 and # 2 FIREWALL VALVE circuit
breakers - In.
n.
CROSSFEED valve switch - Set
alternately to left and right system. Check
that FUEL CROSSFEED light illuminates,
and that the # 1 and # 2 FUEL PRESS
annunciator lights are extinguished.
o.
CROSSFEED valve switch - OFF.
*13.
Fuel quantity indicators - Check as follows:
a.
Fuel quantity indicator selector switch -
MAIN.
b.
Fuel quantity indicators - Compare
indication. With full fuel tanks, left and right
fuel quantity indicators must indicate within
82 pounds of each other with fuel quantity
indicator selector switch set to MAIN.
c.
Fuel quantity indicator selector switch -
AUXILIARY.
d.
Fuel quantity indicators - Compare
indication. With full fuel tanks, left and
right fuel quantity indicators
2-4
|