TM 1-1510-223-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
Do not force the elevator trim system past the limits
which are shown on the PITCH TRIM indicator scale.
8.
Elevator trim - Set to 0 (neutral).
Do not cycle LDG GEAR CONTR handle on the
ground.
9.
Gear- DN.
10.
Keylock switch - ON.
11.
Weather radar - OFF/SBY.
*12.
Fuel control panel - Check the standby pumps
and firewall valves as follows to ensure that they
are powered through the essential bus:
a.
BATTERY switch - OFF.
b.
# 1 and # 2 STANDBY PUMP circuit
breakers - Pull.
c.
# 1 and # 2 FIREWALL VALVE circuit
breakers - Pull.
d.
# 1 and # 2 FIRE PULL handles - Pull to close
firewall valve (listen for valve operation).
e.
STANDBY PUMP switches - ON
(listen for pump operation).
f.
BATTERY switch - ON.
C7-11
g.
# 1 and # 2 FUEL PRESS warning
annunciators - Illuminated.
2-3
|