TM 1-1510-223-MTF
C35.
Stall warning horn sounds continuously.
a.
Defective stall warning transducer.
b.
Defective stall warning test system.
c.
Defective wiring.
d.
Defective stall warning computer.
C36.
Both inverters inoperative.
Defective wiring in inverter system.
C37.
One inverter inoperative.
a.
Tripped inverter circuit breaker (on DC power distribution
panel beneath floor).
b.
Loose or corroded ground connection.
c.
Defective wiring to inverter.
d.
Defective inverter switch.
C38.
BATTERY CHARGE annunciator light inoperative.
a.
Defective light bulb.
b.
Connections on battery shunt loose or corroded.
c.
Defective battery charge monitor module.
C39.
One portion of in terior lighting or lighting control system
inoperative.
a. Defective light circuit board.
b.
Defective light bulbs.
c.
Defective components in overhead control panel.
d.
Defective power supply.
C40.
Fuel crossfeed valve inoperative or
FUEL
PRESS
annunciator light remains illuminated.
a. Defective standby fuel pump.
b.
Defective crossfeed valve.
3-12
|