TM 1-1510-223-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
must indicate within 35 pounds of each
other with fuel quantity indicator selector
switch set to AUXILIARY.
*14.
Pitot tubes (2), stall warning vane, heated fuel
vents (2), and TAS temperature probe - Check
as follows:
Use caution when checking pitot tubes, stall warning vane, heated fuel
vents, and TAS temperature probe for heat by feel. The heating
elements in these items can produce enough heat to cause burns to
personnel who touch them.
a.
STALL WARN heat switch - ON.
b.
PITOT heat switches (2) - ON.
c.
FUEL VENT heat switches (2) - ON.
d.
Left wing heated fuel vent - Check by feel for
heat and condition.
e.
Stall warning vane - Check by feel for heat
and condition.
f.
Left pitot tube - Check by feel for
heat, condition, and free of obstructions.
g.
Right pitot tube - Check by feel for
heat, condition, and free of obstructions.
h.
TAS temperature probe - Check by feel for
heat and condition.
i.
Right wing heated fuel vent - Check by feel
for heat and condition.
2-5
|