|
|
TM 9-2920-225-34
Check that bearing (1) is not damaged. Refer to TM 9-214. If bearing is
1.
damaged, get a new one.
2.
Using multimeter, check rotor (2) for grounds by touching one test probe
of multimeter to rotor shaft (3) and other test probe to one slipring (4).
nonrepairable.
Do step 2 again for other slipring (4).
3.
Using multimeter, check resistance of sliprings (4) by touching ohmmeter test
4.
probes to each slipring. Resistance must be between 1.5 and 2.5 ohms.
If it is not, generator is nonrepairable.
Check slipring (4) runout. Refer to para 2-9e.
5.
Check that rotor shaft (3) is straight. Refer to para 2-9e.
6.
END OF TASK
TA 103676
2-178
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |