TM 9-2815-210-34-2-2
Run-In Schedule - Short (Models LD-465-1 and LD-465-1C)
NOTE
D u r i n g run-in, oil sump temperature shall not
b e more than 260F. Oil pressure is measured
a t engine oil gallery.
G r o s s Brake
Fuel
Duration
E n g i n e Speed
(DF-1 of
Period
(minutes)
(rpm)
VV-F-800)
( b a r e engine)
1
1
0
0
P r e l u b r i c a t e at 25
(minimum)
p s i (measured at
e n g i n e oil gallery)
2
10
Diesel
1200
15
3
15
2000
Diesel
64
4
R e t i g h t e n cylinder head nuts to 130 pound-feet for TD block and
s e t valves immediate y following period 3.
5
15
2400
110
Diesel
6
2600
10
120 to 130
Diesel
7
S e t high speed adjusting screw to limit maximum speed, no load
2850 to 2900 rpm.
8
Set full load
Diesel
2600
126 to 131
power
(62 lb/hr
m a x . fuel
flow )
9
P o w e r check full
1400
3 0 0 pound-
Diesel
load
f e e t torque
(rein)
Diesel
10
Set low idle adjust-
650 to 700
0
ment
11
Diesel
A s needed to check
for leaks
|