TM
9-2815-210-34-2-2
Table 6-5. Run-In Schedule- Long (Model LDS-465-2)
NOTE
D u r i n g run-in, oil sump temperature shall not
b e more than 265F. Oil pressure is measured
a t engine oil gallery.
Fuel
G r o s s Brake
Duration
E n g i n e Speed
( D F - 1 of
( b a r e engine)
VV-F-800)
Period
(minutes)
(rpm)
0
1
0
P r e l u b r i c a t e at 25
(minimum)
p s i (measured at
e n g i n e oil gallery)
22
30
Diesel
2
1000
15
1400
40
Diesel
3
R e t i g h t e n cylinder head nuts to 157 pound-feet and set valves
4
i m m e d i a t e l y following period 3.
15
1600
Diesel
60
5
15
2200
120
Diesel
6
30
2800
160
Diesel
7
30
2800
190 to 200
Diesel
8
9
Set high speed adjusting screw to limit maximum speed, no load
3050 to 3100 rpm.
2800
10
Set full load
195 to 205
Diesel
( 9 2 lb/hr max.
power
f u e l flow)
11
S e t droop screw
1200
(37 to 39 lb/
Diesel
h r fuel flow)
or
Diesel
(44 to 45 lb/
1400
h r fuel flow)
2000
4 2 5 pound-
Diesel
P o w e r check full
12
f e e t torque
load
(min)
( 7 0 lb/hr max.
f u e l flow)
Diesel
13
0
Set low idle adjust-
650 to 700
ment
A s needed to check
14
Diesel
for leaks
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |