TM
9-2815-210-34-2-2
FRAME
4
NOTE
Readings must be within limits given in table 4-59.
The letter L shows a loose fit. I f readings are not
within given limits, throw away part and get a new
one.
1.
M e a s u r e inside diameter of two bypass valve bores (1).
2.
Measure out side diameter of two valve plungers (2).
3.
M e a s u r e fit of each of two valve plungers (2) in its plunger bore (1).
GO TO FRAME 5
Size and Fit
Index
Wear Limit
of New Parts
Item/Point of Measurement
Number
(inches)
(inches)
B y p a s s valve bores inside diameter
1
0.8030 to 0.8040
0.8050
2
Valve plungers out side diameter
0.7990
0.8000 to 0.8010
1 and 2
F i t of plunger in housing bore
0.0060L
0.0020L
to
0.0040L
|