TM 9-2815-210-34-2-2
4-24. CRANKCASE BREATHER TUBE ADAPTER.
There are no special cleaning procedures needed. Refer to
a. Cleaning
c l e a n i n g procedures given in para 4-3.
I n s p e c t i o n and Repair.
b.
FRAME 1
1.
C h e c k that crankcase breather tube adapter (1) is not cracked, bent,
d e n t e d or damaged in any other way. I f crankcase breather tube adapter is
d a m a g e d in any way, get a new part.
WARNING
Dry cleaning solvent is flammable. Do not use near an
o p e n flame. K e e p a fire extinguisher nearby when sol-
v e n t i s u s e d . U s e only in well-ventilated places. Failure
to do this may result in injury to personnel and damage
t o equipment.
C h e c k that crankcase breather tube adapter (1) has no minor nicks,
2.
s c r a t c h e s or burrs. T o take out minor nicks, scratches or burrs, use
a fine mill file or crocus cloth dipped in dry cleaning solvent.
END OF TASK
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |