TM 9-2815-210-34-2-2
FRAME
3
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame.  K e e p a fire extinguisher nearby when
s o l v e n t is used.  U s e only in well-ventilated places.
Failure to do this may result in injury to personnel
a n d damage to equipment.
NOTE
Rocker arm shaft supports (1) cannot be changed
s e p a r a t e l y .  I f any rocker arm shaft support is
d a m a g e d , rocker arm shaft (2) and all three rocker
a r m shaft supports must be changed.
1.
C h e c k that three rocker arm shaft supports (1) are not cracked, nicked or
s c o r e d and have no burrs.  I f rocker arm shaft supports are cracked or
b a d l y scored, throw them away and get new ones. Fix small nicks and burrs
with a fine mill file or crocus cloth dipped in dry cleaning solvent.