FRAME 21
NOTE
R e a d i n g s must be within limits given in table 4-41. The
l e t t e r L shows a loose fit.  If readings are not within
given limits, get a new oil pump.
M e a s u r e depth of pressure pump drive impeller bore (1).
1.
M e a s u r e length A of pressure pump drive impeller (2).
2.
S u b t r a c t measurement in step 1 from measurement in step 2. Result is
3.
c l e a r a n c e between pressure pump drive impeller (2) and top of pressure
p u m p drive impeller bore (1).
GO TO FRAME 22
NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT IN THIS
FRAME. PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES OR ARE CHECKED IN ANOTHER FRAME.
TA 113630
Table 4-41. Engine LDS-465-2 Pressure Pump Drive Impeller
and Drive Impeller Bore Wear Limits
Size and Fit
Wear Limit
of New Parts
Index
(inches)
(inches)
Item /Point of Measurement
Number
P r e s s u r e pump drive impeller
1
1.5600 to 1.5620
1.5635
bore depth
P r e s s u r e pump drive impeller
2
1.5560
1.5565 to 1.5580
length A
C l e a r a n c e between pressure
1 and 2
p u m p drive impeller and top
0.0020L
to
0.0055L
0.0075L
o f drive impeller bore