TM 9-2815-210-34-2-2
FRAME 20
NOTE
R e a d i n g s must be within limits given in table 4-40. The
letter L shows a loose fit. If readings are not within
given limits, get a new oil pump.
M e a s u r e depth of pressure pump driven impeller bore (1).
1.
M e a s u r e length A of pressure pump driven impeller (2).
2.
M e a s u r e clearance between pressure pump driven impeller (2) and top of
3.
pressure pump driven impeller bore (1).
GO TO FRAME 21
T a b l e 4-40. Engine LDS-465-2 Pressure Pump Driven Impeller
and Driven Impeller Bore Wear Limits
Size and Fit
of New Parts
Wear Limit
(inches)
(inches)
I t e m / P o i n t of Measurement
Number
P r e s s u r e pump driven impeller
1
1.5600 to 1.5620
1.5635
bore depth
P r e s s u r e pump driven impeller
2
1.5565 to 1.5580
1.5560
length
1 and 2
C l e a r a n c e between pressure
p u m p driven impeller and top
0.0020L
to
0.0055L
0.0075L
o f impeller bore
max
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |