Click here to make tpub.com your Home Page

Page Title: Table 4-35. Oil Pump Drive Impeller and Impeller Bore Wear Limits
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2815-210-34-2-2
FRAME 15
NOTE
Readings must be within limits given in table 4-35. The
letter L shows a loose fit.  If readings are not within
given limits, get a new oil pump.
Measure depth of pressure pump drive impeller bore (1).
1.
M e a s u r e length A of pressure pump drive impeller (2).
2.
M e a s u r e clearance between pressure pump drive impeller (2) and top of
3.
p r e s s u r e pump drive impeller bore (1).
GO TO FRAME 16
Table 4-35. Oil Pump Drive Impeller and Impeller Bore Wear Limits
Size and Fit
Wear Limit
of New Parts
Index
(inches)
(inches)
Item /Point of Measurement
Number
Pressure pump drive impeller
1
1.3820
1.3770 to 1.3790
bore depth
P r e s s u r e pump drive impeller
2
1.3705
1.3735 to 1.3750
length A
1and2
C l e a r a n c e between pressure
p u m p drive impeller and top
0.0020L
0.0020L
to
0.0055L
o f drive impeller bore
max