TM 9-2815-210-34-2-2
FRAME 16
NOTE
Readings must be within limits given in table 4-36. The
letter L shows a loose fit. If readings are not within
given limits, get a new oil pump.
Measure depth of scavenge pump driven impeller bore (1).
1.
M e a s u r e length A of scavenge pump driven impeller (2).
2.
M e a s u r e clearance between scavenge pump driven impeller (2) and top of
3.
s c a v e n g e pump driven impeller bore (1).
M e a s u r e depth of scavenge pump drive impeller bore (3).
4.
5.
M e a s u r e length B of scavenge pump drive impeller (4).
M e a s u r e clearance between scavenge pump drive impeller (4) and top of
6.
s c a v e n g e pump drive impeller bore (3).
END OF TASK
4-177
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |