TM 9-2815-210-34-2-2
4-15. OIL GAGE ROD, ROD SUPPORT, AND SUPPORT BRACKET.
a "Cleaning.
FRAME
1
WARNING
D r y cleaning solvent is flammable. Do not use near
a n open flame. K e e p a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
F a i l u r e to do this may result in injury to personnel
a n d damage to equipment.
E y e shields must be worn when using compressed air.
E y e injury can occur if eye shields are not used.
1.
C l e a n inside of rod support (1) using brass wire probe. Flush inside of rod
s u p p o r t w i t h d r y c l e a n i n g s o l v e n t . B l o w inside of rod support dry with
2.
C l e a n outside of rod support (1) with dry cleaning solvent. Clean off sludge
a n d gum using a stiff brush. Dry with clean cloth.
3.
T a k e preformed packing (2) off oil gage rod (3) and throw it away.
4.
Clean oil gage rod (3), support bracket (4), screw (5), nut (6), and washer
( 7 ) with dry cleaning solvent. Dry with clean cloth.
END OF TASK
|