TM 9-2815-210-34-2-2
4-14. COOLANT DRAIN COCK AND OIL PRESSURE TRANSMITTER.
a.
Cleaning.
FRAME 1
WARNING
Dry cleaning solvent is flammable. Do not use near
a n open flame. K e e p a fire extinguisher nearby
w h e n solvent is used, U s e only in well-ventilated
p l a c e s . Failure to do this may result in injury to
p e r s o n n e l and damage to equipment.
1.
C l e a n oil pressure transmitter (1) with dry cleaning solvent. Dry with clean
cloth.
2.
C l e a n pipe adapter (2), drain cock (3), and two elbows (4) with brass wire
probe.
W a s h pipe adapter (2), drain cock (3), and t w o elbows (4) by flushing with
3.
dry cleaning solvent.
WARNING
E y e shields must be worn when using compressed air.
E y e injury can occur if eye shields are not used.
4.
D r y pipe adapter (2), drain cock (3), and two elbows (4) by blowing them out
w i t h dry, compressed air.
END OF TASK
|