TM 9-2815-210-34-2-2
AIR COMPRESSOR SUPPORT.
a.
Clesning.
FRAME 1
1.
Unscrew and takeout pipe plug (1)..
WARNING
D r y cleaning solvent is flammable. Do not use near
an open flame. K e e p a fire extinguisher nearby when
s o l v e n t i s u s e d . U s e only in well-ventilated places.
F a i l u r e to do this may result in injury to personnel and
d a m a g e to equipment.
2.
Clean support (2) with dry cleaning solvent. Dry with clean cloth.
3.
C l e a n oil passages (3) with a brass wire probe.
4. Wash oil passages (3) by flushing with dry cleaning solvent.
WARNING
E y e shields must be worn when using compressed air.
E y e injury can occur if eye shields are not used.
D r y oil passages (3) by blowing them out with dry, compressed air.
5.
END OF TASK
|