TM 9-2520-246-34-1
FRAME 3
NOTE
Readings must be within limits given in table 2-30.
If readings are not within given limits, throw away
part and get a new one.
Measure shifter shaft bore (1).
1.
Measure expansion plug outside diameter (2).
2.
Measure input shaft rear bearing bore (3).
3.
Measure countershaft rear bearing bore (4).
4.
Measure rear output shaft rear bearing bore (5).
5.
GO TO FRAME 4
Transfer Case Bearing Bores Wear Limits
Table 2-30.
Size and Fit
of New Parts
Wear Limit
Index
(inches)
(inches)
Number
Item/Point of Measurement
1.2514
1.247 to 1.249
Shifter shaft bore
1
None
1.256 to 1.260
Expansion plug outside diameter
2
3.9368 to 3.9378
3.9382
Input shaft rear bearing bore
3
4.0012
4.000 to 4.001
Countershaft rear bearing bore
4
3.8765
3.8750 to 3.8760
Rear output shaft rear bearing
5
bore
2-190
|