E-8. M1089 SOLENOID TEST ADAPTER
Assemble the M1089 solenoid test adapter according to the following steps. Refer to the following parts list and Figure
E-12. M1089 Solenoid Test Adapter for details.
Part Number
Material Description
National Stock
Qty
Number
2-2-2 080401CA
Tee, Tube
1
2-2 080202CA
Elbow, Pipe to Tube
1
4-2 130140B
Bushing, Pipe
1
NB-2-031
Tubing, Nonmetallic
24 in.
Figure E-12. M1089 Solenoid Test Adapter
a.
All dimensions are in inches (millimeters).
b.
Cut one piece of nonmetallic tubing (1) to 6.0 in. (152.4 mm) long.
c.
Cut one piece of nonmetallic tubing (2) to 18.0 in. (457.2 mm) long.
c.
Remove three nuts (3) and ferrule sleeves (4) from tube tee (5).
d.
Install two nuts (3) and ferrule sleeves (4) on nonmetallic tubing (1).
e.
Install nonmetallic tubing (1) on tube tee (5).
f.
Remove nut (6) and ferrule sleeve (7) from pipe to tube elbow (8).
g.
Install two nuts (3 and 6) and ferrule sleeves (4 and 7) on nonmetallic tubing (2).
h.
Install nonmetallic tubing (2) on tube tee (5).
i.
Install nut (6) on pipe to tube elbow (8).
j.
Install pipe bushing (9) on pipe to tube elbow (8).