TM 9-2320-366-20-3
7-72. 100 AMP ALTERNATOR TO REVERSE POLARITY RELAY 12 VDC
CABLE REPLACEMENT (CONT)
(4) Install dust boot (6) on 100 amp alternator to reverse
polarity relay 12 vdc cable (2).
CAUTION
Insulation washer must be installed with flat
side up. Failure to comply may result in
damage to equipment.
(5) Position terminal lug TL60 (7) on alternator (8) with
insulator washer (9), washer (10) and self-locking nut
(11).
(6) Tighten self-locking nut (11) to 40 lb-in. (5 N m).
(7) Position dust boot (6) on terminal lug TL60 (7).
(8) Position terminal lugs TL61 (12) and TL47 (13) on
reverse polarity relay 12 VDC LOAD terminal (14) with
lockwasher (15) and nut (16).
(9) Tighten nut (16) to 120-144 lb-in. (14-16 Nm).
(10) Position terminal cover (17) on terminal lugs TL47 (13)
and TL61 (12).
(11) Position turbocharger intake hose (18) on intake air
cleaner boot (19) with clamp (20).
(12) Tighten clamp (20) to 36-48 lb-in. (4-5 Nm).
|