TM 9-2320-366-20-3
(5) Lift dust boot (10) on terminal lug TL60 (11).
(6) Remove self-locking nut (12), washer (13), insulation
washer (14), and terminal lug TL60 (11) from alternator
(15). Discard self-locking nut.
(7) Remove dust boot (10) from 100 amp alternator to
reverse polarity relay 12 vdc cable (16).
(8) Remove three screws (17), washers (18), clamps (19),
and 100 amp alternator to reverse polarity relay 12 vdc
cable (16) from engine (20).
(9) Remove three clamps (19) from 100 amp alternator to
reverse polarity relay 12 vdc cable (16).
b. Installation.
(1) Install three clamps (1) on 100 amp alternator to reverse
polarity relay 12 vdc cable (2).
NOTE
Install plastic cable ties as required.
(2) Position 100 amp alternator to reverse polarity relay 12
vdc cable (2) on engine (3) with three clamps (1),
washers (4), and screws (5).
(3) Tighten three screws (5) to 22-27 lb-ft (31-37 Nm).
Change 1