TM 9-2320-366-20-3
NOTE
Tag cables and connection points prior to
disconnecting.
(1) Remove nut (1) and lockwasher (2) from battery ground
cable (3). Discard lockwasher.
(2) Deleted.
(3) Remove terminal lugs TL50A (5), TL48 (6), battery
tester terminal lug (7) and washer (4) from battery
ground cable (3).
NOTE
Remove battery terminal covers as required.
(4) Loosen two terminal screws (8) on battery ground cable
(3).
(5) Remove battery ground cable (3) from battery terminals
BT4 E2 (9) and BT3 E2 (10).
(6) Remove nut (11) and terminal lug TL99 (12) from
battery BT2 to BT4 12 vdc cable (13).
Change 1
|