d. Toggle Switch Installation.
(1) Connect four wires (1) to toggle switch (2).
NOTE
Keyway of toggle switch aligns with keyway
slot in mounting hole.
(2) Position toggle switch (2) in mounting hole (3).
(3) Install switch guard cover (4) on toggle switch (2) with
nylon washer (5) and nut (6).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area. If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water. Failure
to comply may result in injury to
personnel.
(4) Apply adhesive to seating surface (7).
(5) Connect connector (8) to boom up/down controller (9).
(6) Position boom up/down controller (9) in REMOTE
CONTROL UNIT (10).
Change 1
7-193
|