|
|
TM 9-2320-366-20-3
7-32. REMOTE CONTROL UNIT REPAIR (CONT)
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area.
If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap
and water. Failure to comply may result in injury to personnel.
(7) Apply adhesive to the first 2 to 5 threads of mounting
studs (11).
(8) Position four self-locking nuts (12) on boom up/down
controller (9).
(9) Tighten four self-locking nuts (12) to 14 lb-in. (2 Nm).
NOTE
Adhesive requires 24 hours to cure.
(10) Spread excess adhesive over heads of four self-locking
nuts (12).
e. Harness Removal.
NOTE
All four controllers are removed for harness
removal.
All four controllers are removed the same way.
Boom Up/Down controller shown.
(1) Remove four self-locking nuts (1) from boom up/down
controller (2). Discard self-locking nuts.
(2) Remove boom up/down controller (2) from REMOTE
CONTROL UNIT (3) until connector (4) is accessible.
(3) Disconnect connector (4) from boom up/down controller
(2).
(4) Remove adhesive from seating surface (5).
7-194
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |