TM 9-2320-366-20-3
(7) Lift dust boot (14) on terminal lug TL80 (15).
(8) Remove nut (16), lockwasher (17), and terminal lug TL80
(15) from 100 amp reverse polarity relay (9). Discard
lockwasher.
(9) Lift terminal cover (18) on terminal lugs TL1 (19), TL37
(20) and TL36 (21).
(10) Remove nut (22), lockwasher (23), and terminal lugs TL1
(19), TL37 (20), and TL36 (21) from 100 amp reverse
polarity relay (9). Discard lockwasher.
(11) Remove six self-locking nuts (24), spring washers (25),
screws (26), and 100 amp reverse polarity relay (9) from
bracket (27). Discard spring washers and self-locking
nuts.
b.
Installation.
(1) Position 100 amp reverse polarity relay (1) on bracket (2)
with six screws (3), spring washers (4), and self-locking
nuts (5).
(2) Tighten six screws (3) to 60-72 lb-in. (7-8 Nm).
7-185
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |