TM 9-2320-366-20-3
7-30. 100 AMP REVERSE POLARITY RELAY REPLACEMENT (CONT)
(3) Position terminal lugs TL36 (6), TL37 (7), and TL1 (8) on
100 amp reverse polarity relay (1) with lockwasher (9)
and nut (10).
(4) Tighten nut (10) to 120-144 lb-in. (14-16 Nm).
(5) Position terminal cover (11) on terminal lugs TL36 (6),
TL37 (7), and TL1 (8).
(6) Position terminal lug TL80 (12) on 100 amp reverse
polarity relay (1) with lockwasher (13) and nut (14).
(7) Tighten nut (14) to 120-144 lb-in. (14-16 Nm).
(8) Position dust boot (15) on terminal lug TL80 (12).
(9) Position terminal lug TL44 (16) on 100 amp reverse
polarity relay (1) with lockwasher (17) and nut (18).
(10) Tighten nut (18) to 120-144 lb-in. (14-16 Nm).
(11) Position dust boot (19) on terminal lug TL44 (16).
(12) Position terminal lug TL47 (20) and TL61 (21) on 100
amp reverse polarity relay (1) with lockwasher (22) and
nut (23).
(13) Tighten nut (23) to 120-144 lb-in. (14-16 Nm).
(14) Position terminal cover (24) on terminal lugs TL47 (20)
and TL61 (21).
7-186
|