TM 9-2320-366-20-3
7-28. M1089 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT)
(23) Install overload shutdown system cable (46) in junction
box (1) with four screws (47), lockwashers (48), and nuts
(49).
(24) Install quick disconnect terminal (50) on ground strip (12)
position 3.
(25) Install four terminal lugs (51) on terminal block (17)
positions 1, 17 and 19 with three screws (52).
(26) Install boom down lockout solenoid cable (53) in junction
box (1) with conduit nut (54).
7-178
|