7-28. M1089 JUNCTION BOX ASSEMBLY REPLACEMENT/REPAIR (CONT)
NOTE
Perform steps (10.1) through (10.3) on
junction boxes that have had modification kit
installed.
(10.1)Install bracket (29.2) on junction box (2) with two
rivets (29.8).
(10.2) Install shutdown relay (29.1) on bracket (29.2) with
screw (29.3), washer (29.4), lockwasher (29.5) and
nut (29.6).
(10.3) Connect shutdown relay connector (29.7) to
shutdown relay (29.1).