TM 9-2320-366-20-3
7-2. 100 AMP ALTERNATOR REPLACEMENT (CONT)
(6)
Remove screw (13), washer (14), and clamp (15)
from alternator (6).
(7)
Lift dust boot (16) on terminal lug TL2 (17).
(8)
Remove self-locking nut (18), washer (19), terminal
lugs TL2 (17) and TL6 (21), and two washers (22)
from alternator (6).
(9)
Position two washers (22), washer (19), and self-
locking nut (18) on alternator (6).
(10) Lift dust boot (23) on terminal lug TL35 (24).
(11) Remove self-locking nut (25), washer (26), and
terminal lug TL35 (24) from voltage regulator (27).
(12) Position washer (26) and self-locking nut (25) on
voltage regulator (27).
(13) Lift dust boot (28) on terminal lug TL110 (29).
NOTE
Perform steps (14) and (15) on vehicles
equipped with alternator P/N N1506-1
(12420852).
(14) Remove self-locking nut (30), washer (31), and
terminal lug TL110 (29) from voltage regulator (27).
(15) Position washer (31) and self-locking nut (30) on
voltage regulator (27).