TM 9-2320-366-20-3
(9) Loosen two screws (12) in clamps (13) as far as possible
without disengaging screws from D-nuts (14).
(10) Unhook clamp tabs (15) from tab windows (16).
CAUTION
Clamp tongue must be started in clamp groove.
Failure to comply may result in damage to
equipment.
Position clamps with screw heads facing forward
so they do not interfere with alternator mount.
(11) Position coolant hose (17) on water pump (3).
(12) Position two clamps (13) on coolant hose (17).
(13) Engage as many clamp tabs (15) as possible in tab
windows (16) allowing little or no play between clamp
and coolant hose (17).
(14) Tighten two clamps (13) to 13-17 lb-in. (2 Nm).
NOTE
Minimum allowable gap on clamp is 0.2 in. (5
mm). If gap is less than 0.2 in. (5 mm),
remove and re-install clamp.
(15) Measure gap on two clamps (13).
(16) Install preformed packing (18) and 45-degree fitting (19)
in water pump (3).
(17) Connect heater supply tube (20) to 45-degree fitting (3).